FnB: E waiter app unable to login for first time setup
Question :
E waiter app unable to login for first time setup
Login Unsuccessful
Failed to connect server.
NETWORK_ERROR
Possible Reason :
1. Error message may be prompted though you have configured e-waiter IP address and port number correctly.
2. This probably because AutoCount FNB Front End Open Firewall Port blocked by Windows access rights.
Solution :
Right click AutoCount FnB POS 5.0 icon on desktop, and click on Properties.
Click on Compatibility Tab, check the checkbox of Run this program as an administrator, and click on OK to proceed
Reconfigure again Ewaiter IP address and Port Number.
By: Kee 20200719, Jacky 20200731, P200805 [000084]
AutoCount Accounting 1.8 / 1.9
|
AutoCount Payroll
|
AutoCount POS
|
AutoCount On The Go
|
AutoCount Accounting Plug-In Documentations
|