Pos3/5/FNB: When run POS Sync Monitor program, system will pop up error message
Question :
When run pos sync monitor program, system will pop up error message.
Invoke or BeginInvoke cannot be called on a control until the window handle has been created.
System.InvalidOperationException: Invoke or BeginInvoke cannot be called on a control until the window handle has been created.
Possible Reason :
Your windows resolution may not meet the program minimum system requirement (Minimum windows resolution requirement is : 1024 x 768).
Solution :
1. Go to Windows Display Setting > Change the display resolution to minimum 1024 x 768 and above)
2. Now you should be able to run POS Sync Monitor program.
By: Kee 20230718, Jacky 20230721, P230721 [000428]