Question : When I try to login, an error message prompted: Unknown Sql Exception (Number=3906, Message=Failed to update database “AED_AIMI” because the database in read-only)?

Version : 1.8 / 1.9 / 2.0

Readonly1.png


Possible Reason :

This database is in Read-Only Mode.

Readonly2.png


Solution :

1) Go to SQL Management Studio, double click on Database.

Readonly3.png


2) Right click on database AED_AIMI, and click on Properties.

Readonly4.png


3) Go to Options > Database Read – Only, change the value from True to False, and click on OK.

Readonly5.png


4) Then click on Yes.

Readonly6.png


Now you should be able to login AutoCount for this account book.


Note : Please seek assistance from your software dealer if the problem still persists after performing the suggested steps.