Troubleshooting: Login Error - Database is read-only
Question : When I try to login, an error message prompted: Unknown Sql Exception (Number=3906, Message=Failed to update database “AED_AIMI” because the database in read-only)?
Version : 1.8 / 1.9 / 2.0
Possible Reason :
This database is in Read-Only Mode.
Solution :
1) Go to SQL Management Studio, double click on Database.
2) Right click on database AED_AIMI, and click on Properties.
3) Go to Options > Database Read – Only, change the value from True to False, and click on OK.
4) Then click on Yes.
Now you should be able to login AutoCount for this account book.
Note : Please seek assistance from your software dealer if the problem still persists after performing the suggested steps.
By : Aimi 200814, Lay Swan 200821, P200824
AutoCount Accounting 1.8 / 1.9
|
AutoCount Payroll
|
AutoCount POS
|
AutoCount On The Go
|